N2 Blast Nitrogen generator for dry sprinkler systems
Dry sprinkler systems are not dry. This sounds contradictory, but it is not. Upon delivery and also after, the systems are tested regularly. When testing, water is forced into the system. After testing, there is always water and moisture left behind. It is precisely in that little bit of water in dry systems that the MIC bacteria thrive very well. We come across systems less than three years old with corrosion and damage.
Our N2 Blast nitrogen generator prevents this problem. By simply injecting 98% nitrogen into the system you permanently prevent and combat corrosion and this offers advantages. The life of the system is greatly extended, leaks and blocked sprinklers are prevented, no more expensive repairs, increased fire safety and the TCO is always predictable.
Advantages N2Blast generators:
- Energy-efficient PSA technology More information about this technology – click here
- Proven technology
- Developed for dry sprinkler systems
- For systems from 1,900 to 85,000 liters
- Safe due to low pressure and small buffer tanks
- Leak rates according to NFPA 13 and NFPA25
- FM Global approval
The N2 Blast generator is the solution against corrosion in dry sprinkler systems. We offer several types.
The N2 Blast DeOx line for wet sprinkler systems
For wet sprinkler systems, Deox series nitrogen generators can be a solutions for very special applications. A microfilter is used to extract oxygen from the water. The Deox series is designed to pre-fill any wet sprinkler system with ultrapure nitrogen gas and effectively remove up to 99.5% of the oxygen from the system. Without oxygen, mic corrosion will not have a chance to damage your sprinkler system. Another application to prevent corrosion in your sprinkler system is our additive PipeShield. Click here for more information.
Do you also want leaks and clogged sprinklers to be prevented?
Download datasheets, manuals and information here
- Quick-Check Portable N2 Purity Sensor: Manual
- DeOxygenation Systems: Manual
- AutoPurge System / Sample Port Autopurge features
- AutoPurge Timer Features
- Dual and Single Vent O2-Release: Features
N2Blast Line
- N2Blast – FPS-500: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-900: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-1650: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-3250: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-5000: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-10000: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-16500: Datasheet, Installation Layout Drawing and O&M Manual
- N2Blast – FPS-22500: Datasheet, Installation Layout Drawing and O&M Manual
Legacy N2 Blast Line
- N2Blast – FPS-650: Installation Layout Drawing and O&M Manual
- N2Blast – FPS-1250: Installation Layout Drawing and O&M Manual
DeOx™ Line for wet sprinkler systems
- N2INERT System & High Pressure Regulator Kit:
Manual - DeOx™ – Water Deoxygenation System:
Datasheet, Brochure, Guide Specification, DeOx FPS 1 O&M Manual and DeOx FPS 1 O&M Manual - DeOx™ – N2Inert System™:
Datasheet, Brochure and O&M Manual - DeOx™ – Single Vent O2-Release System™:
Datasheet and Brochure - Dual Vent O2-Release System™:
Datasheet, Brochure and O&M Manual